Data Postprocessing
Raw data from wireless channel measurement campaigns, as present in this dataset, takes a lot of file storage capacity. Any reduction, e.g., via undersampling, is usually directly related to a loss of accessible channel properties. For example, a reduction of bandwidth will result in a loss of delay (or fast-time) resolution. However, with some reasonable assumptions about our objects of interest, we can reduce the amount of data without losing too much information.
Note
For ease-of-processing and sharing, we have reduced the total disk space requirements of our dataset to 200 GB. The full data takes a total of 4 TB of disk space.
We also outline the remaining postprocessing steps here, that are not directly related to the reduction of data size. They rather deal with accounting for the legal aspects in the used frequency band, synchronization error corrections, and how the CIRs (Channel Impulse Responses) are extracted.
Rx Systems
The configuration parameters of our measurement system were introduced in the Measurement section. Here, we only call out the one derived parameter not listed there:
| Parameter | Value | Comment |
|---|---|---|
| Subcarrier Spacing | 62.5 kHz | Inverse of Symbol length |
To avoid violation of spectral mask requirements for the used frequency band, we did not use the full 100 MHz bandwidth. Instead, the subcarriers at the edges of the band were used as a guardband (in addition to bandpass filters at the transmitter). This results in a usable bandwidth of 80 MHz. The first step in the preprocessing is hence to remove the unused subcarriers, which already reduces the data size by 20%.
In addition, we performed a synchronization error correction based on the errors logged by the FS740 oscillators.
B2B Calibration and Channel Deconvolution
The received signal does not correspond to the desired CIRs ; instead, is a superposition of multiple, differently shifted and distorted copies of the transmitted signal . In frequency-domain notation we can write
To obtain the CIRs we need to perform deconvolution of the received signal with the transmitted signal via
This works because we use a multi-sine measurement signal with a nearly constant envelope for , so there are no zeros in the signal that would result in a division by zero. In this step we use instead of , which we obtain from a Back-to-Back (B2B) calibration measurement. The setup for the B2B calibration measurement is illustrated in the following figure.
Note
Figure of the B2B calibration setup is coming soon.
The B2B calibration measurement is performed by connecting the Tx sequentially to each Rx by a coaxial cable. Using the same Tx and Rx hardware as in the measurement, we recorded 1 minute of data for each Tx-Rx combination. By also accounting for the frequency response of the coaxial cable, we can then (ideally) remove the frequency response of most used hardware components, except for the antennas. To obtain , we first averaged over the frequency domain of all OFDM symbols in and computed
Hence, using for the deconvolution means the resulting CIRs:
- do not contain the frequency response of the Tx and Rx hardware
- do not contain the frequency response of the coaxial cables in the measurements (measured with a VNA)
- do not contain the transmitted waveform
- do contain the frequency response of the antennas
Finally, after applying a delay correction to , the CIRs are obtained by computing
Averaging and Downsampling
At this point, the measurement data is still stored uncompressed and takes a sizeable amount of disk space. As the data still has a high slow-time sampling rate, corresponding to the OFDM symbol length of , we decided to downsample the data in the slow-time domain. Delay and Doppler are independent in this type of data (see Signal Model below), so this only affects the Doppler-shift term and does not affect the delay resolution.
The original Doppler-shift observable with this signal is bounded by the Subcarrier Spacing :
This corresponds to a Doppler-Bandwidth of .
To compute the maximum Doppler-shift in the scenarios we need to consider the formula for the multistatic Doppler-shift with static transmitter and receiver positions:
We can see that the maximum Doppler-shift occurs when the cosine terms have a magnitude of 1; the maximum Doppler-shift is then given by:
With the carrier frequency of the signal (3.75 GHz) and the narrowband approximation we get:
For the UAV, we know the magnitude of the velocity vector at all times does not exceed (40 km/h). However, due to the urban propagation environment, we also need to consider other possible sensing targets, such as pedestrians, bicyclists, trains, and more. With some backoff factor, we decided on a maximum velocity limit of (180 km/h). The maximum required Doppler-shift in this case is given by:
which corresponds to a required Doppler-Bandwidth of .
To simplify the downsampling effort, we decided on an integer downsampling factor of , which results in an achievable Doppler-shift range of , and therefore:
This comfortably exceeds the required 2500 Hz.
Simply dropping 19 out of every 20 samples in would result in an SNR loss for the subsequent correlations. Instead, we perform the downsampling by averaging over 20 consecutive symbols, resulting in a slow-time sampling interval of .
Final Signal Parameters
This postprocessing results in the final signal parameters of the data in this dataset. For brevity, the following table only shows the changes with respect to the original signal parameters.
| Parameter | Value |
|---|---|
| Bandwidth | 80 MHz |
| Delay Resolution | 12.5 ns |
| Subcarrier Spacing | 62.5 kHz |
| Slow-Time Sampling Interval | 320 |
| Doppler-Bandwidth | 3.124 kHz |
Note
Doppler resolution () is not listed here, as it depends on the coherent observation time chosen during processing (e.g. the slow-time window size), rather than being fixed by the dataset itself.
Signal Model
A common way to represent this type of channel sounding data is as a sum over propagation paths (the direct path, the UAV reflection, and any clutter), each described by a complex amplitude , a delay , and a Doppler frequency :
The two exponentials separate cleanly by variable: encodes each path’s delay along the frequency axis — the fast-time domain — while encodes its Doppler shift along the time axis — the slow-time domain. This is why reducing the measurement bandwidth costs delay (fast-time) resolution, while the slow-time downsampling described above only costs Doppler resolution.